- Inductive Halfbridge
- ± 2.0 mm Measuring Stroke
- 4.6 mm Total Stroke
- 0.05 mm Repeatability
- Supply: 5V
- Power Consumption: 120 mW [Run] / 15 mW [Idle]
Intelligent transducer with integrated signal conditioning and digital interface. Used for the same applications as our standard transducers with an 8h6 body diameter.
Measuring stroke ± 2.0 mm and total stroke 4.6 mm. Pretravel not adjustable. Spring push, Vacuum retract, and pneumatic options available. Plug DIN M5, cable exit axial.
Measuring Systems
- Inductive Halfbridge coil system with core. Integrated conditioning electronics with system error correction.
Connections
- Connection to transducer – Sensor plug M5, 4 pole
- Cable – PUR, pigtail with 200 mm length
- Connection to electronics – Sensor plug M8, 4 pole
Interface
- Freely documented point-to-point protocol on RS485 base, termination 120 ohm.
- Connection to sensor with 4 wire cable, M5 plug on the sensor side, M8 plug on the electronic side.
- Baud rates 9600 bit/s, 115200 bit/s, 10 kbit/s, 500 kbit/s and 1 Mbit/s.
- Sensor information for test equipment monitoring, SPS-profiles and objects.
Technical data
Cable exit: 'A' Axial 'R' Radial | 3TLX10A DG / 3TLX10R DG | 3TLX10AV DG / 3TLX10RV DG | 3TLX10AP DG / 3TLX10RP DG | 3TLX10AL DG / 3TLX10RL DG |
---|---|---|---|---|
Total stroke | 4.6 mm | 4.6 mm | 4.6 mm | 4.6 mm |
Measuring stroke (symmetrical) | ± 2.0 mm | ± 2.0 mm | ± 2.0 mm | ± 2.0 mm |
Pre-travel | Symmetrical, not adjustable | Symmetrical, not adjustable | Symmetrical, not adjustable | Symmetrical, not adjustable |
Bearing | ball bearing no side-play | ball bearing no side-play | ball bearing no side-play | ball bearing no side-play |
Lifetime | >10 Mio. Cycles | >10 Mio. Cycles | >10 Mio. Cycles | >10 Mio. Cycles |
Tip rotation | 1° over full stroke | 1° over full stroke | 1° over full stroke | 1° over full stroke |
Temperature range | -10 to +65°C, storage and operation | -10 to +65°C, storage and operation | -10 to +65°C, storage and operation | -10 to +65°C, storage and operation |
Mounting position | Any | Any | Any | Any |
Tip | 3 mm tungsten carbide ball, M2.5 fixing thread | 3 mm tungsten carbide ball, M2.5 fixing thread | 3 mm tungsten carbide ball, M2.5 fixing thread | 3 mm tungsten carbide ball, M2.5 fixing thread |
Bellow | FPM / FKM | FPM / FKM | FPM / FKM | - |
Body diameter | 8h6 | 8h6 | 8h6 | 8h6 |
Plug | DIN M5 | DIN M5 | DIN M5 | DIN M5 |
Advance | - | - | pneumatic | pneumatic |
Lift off | none | Vacuum | Return spring | Return spring |
Maximum pressure | - | - | 1.5 bar | 4.5 bar |
Spring rate | 0.63 N at electrical zero (tolerance ± 20%) | 0.63 N at electrical zero (tolerance ± 20%) | Approx. 1.0 N at 0.8 bar approx. 0.6 N at 0.6 bar | Approx. 1.0 N at 1.1 bar approx. 0.6 N at 0.8 bar (at electrical zero) |
0.16 N – 4.0 N optional | 0.16 N – 1.0 N optional | (at electrical zero) | ||
Measuring system | Inductive halfbridge | Inductive halfbridge | Inductive halfbridge | Inductive halfbridge |
Repeatability | 0.05 mm | 0.05 mm | 0.05 mm | 0.05 mm |
Error limit | ± 1.0 mm (at 20°C ±1°C) | ± 1.0 mm (at 20°C ±1°C) | ± 1.0 mm (at 20°C ±1°C) | ± 1.0 mm (at 20°C ±1°C) |
Interface | Communication protocol for digital IMT transducers | Communication protocol for digital IMT transducers | Communication protocol for digital IMT transducers | Communication protocol for digital IMT transducers |
Transfer rate | 4000 measuring / sec | 4000 measuring / sec | 4000 measuring / sec | 4000 measuring / sec |
Supply / Power consumption | 5V | 5V | 5V | 5V |
120 mW [Run] | 120 mW [Run] | 120 mW [Run] | 120 mW [Run] | |
15 mW [Idle] | 15 mW [Idle] | 15 mW [Idle] | 15 mW [Idle] | |
Repair | Partially possible | Partially possible | Partially possible | Partially possible |