IMT/MDT Miniture Series

File Download
Link

MDT Displacement transducers

  • Used in demanding environments where space is at a premium
  • Typical applications include: Materials testing, Automotive & Aerospace test rigs and actuators, Load cells, Pressure transducers, Weighing systems, Closed loop control applications
  • Range: ±0.25 – ±50mm
  • Repeatability <0.1% stroke length
  • Sealed to IP55
  • Standard temperature range: -50°C – 85°C
  • Options for -50°C – 200°C
  • Stainless steel construction
IMT/M series miniature displacement transducer

The ranges of miniature LVDT displacement transducers are ideal where space is limited. Measuring ranges cover from ±0.25mm to ±50mm and a series of options are available as shown in the selection chart below.

Their small size make them suitable for OEM applications in load cells, pressure transducers, weighing systems and closed-loop control. The low mass of the core can also be advantageous in projects having minimal weight restrictions.


Data sheet

Posted on

IMT/EDT Economy Series

File Download
Link

MDT Displacement transducers

  • Used in demanding environments where space is at a premium
  • Typical applications include: Materials testing, Automotive & Aerospace test rigs and actuators, Load cells, Pressure transducers, Weighing systems, Closed loop control applications
  • Range: ±0.25 – ±50mm
  • Repeatability <0.1% stroke length
  • Sealed to IP55
  • Standard temperature range: -50°C – 85°C
  • Options for -50°C – 200°C
  • Stainless steel construction
IMT/M series miniature displacement transducer

The ranges of miniature LVDT displacement transducers are ideal where space is limited. Measuring ranges cover from ±0.25mm to ±50mm and a series of options are available as shown in the selection chart below.

Their small size make them suitable for OEM applications in load cells, pressure transducers, weighing systems and closed-loop control. The low mass of the core can also be advantageous in projects having minimal weight restrictions.


Data sheet

Posted on

3TLX10 DG Series (± 2.0 mm)

  • Inductive Halfbridge
  • ± 2.0 mm Measuring Stroke
  • 4.6 mm Total Stroke
  • 0.05 mm Repeatability
  • Supply: 5V
  • Power Consumption: 120 mW [Run] / 15 mW [Idle]

Intelligent transducer with integrated signal conditioning and digital interface. Used for the same applications as our standard transducers with an 8h6 body diameter. 

Measuring stroke ± 2.0 mm and total stroke 4.6 mm. Pretravel not adjustable. Spring push, Vacuum retract, and pneumatic options available. Plug DIN M5, cable exit axial.

Measuring Systems

  • Inductive Halfbridge coil system with core. Integrated conditioning electronics with system error correction.

Connections

  • Connection to transducer – Sensor plug M5, 4 pole 
  • Cable – PUR, pigtail with 200 mm length 
  • Connection to electronics – Sensor plug M8, 4 pole

Interface

  • Freely documented point-to-point protocol on RS485 base, termination 120 ohm.
  • Connection to sensor with 4 wire cable, M5 plug on the sensor side, M8 plug on the electronic side.
  • Baud rates 9600 bit/s, 115200 bit/s, 10 kbit/s, 500 kbit/s and 1 Mbit/s.
  • Sensor information for test equipment monitoring, SPS-profiles and objects.


Technical data

Cable exit:
'A' Axial
'R' Radial
3TLX10A DG / 3TLX10R DG3TLX10AV DG / 3TLX10RV DG3TLX10AP DG / 3TLX10RP DG3TLX10AL DG / 3TLX10RL DG
Total stroke4.6 mm4.6 mm4.6 mm4.6 mm
Measuring stroke (symmetrical)± 2.0 mm± 2.0 mm± 2.0 mm± 2.0 mm
Pre-travelSymmetrical, not adjustableSymmetrical, not adjustableSymmetrical, not adjustableSymmetrical, not adjustable
Bearingball bearing no side-playball bearing no side-playball bearing no side-playball bearing no side-play
Lifetime>10 Mio. Cycles>10 Mio. Cycles>10 Mio. Cycles>10 Mio. Cycles
Tip rotation1° over full stroke1° over full stroke1° over full stroke1° over full stroke
Temperature range-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation
Mounting positionAnyAnyAnyAny
Tip3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread
BellowFPM / FKMFPM / FKMFPM / FKM-
Body diameter8h68h68h68h6
PlugDIN M5DIN M5DIN M5DIN M5
Advance--pneumaticpneumatic
Lift offnoneVacuumReturn springReturn spring
Maximum pressure--1.5 bar4.5 bar
Spring rate0.63 N at electrical zero (tolerance ± 20%)0.63 N at electrical zero (tolerance ± 20%)Approx. 1.0 N at 0.8 bar approx. 0.6 N at 0.6 bar Approx. 1.0 N at 1.1 bar approx. 0.6 N at 0.8 bar (at electrical zero)
0.16 N – 4.0 N optional0.16 N – 1.0 N optional(at electrical zero)
Measuring systemInductive halfbridgeInductive halfbridgeInductive halfbridgeInductive halfbridge
Repeatability0.05 mm0.05 mm0.05 mm0.05 mm
Error limit ± 1.0 mm (at 20°C ±1°C) ± 1.0 mm (at 20°C ±1°C) ± 1.0 mm (at 20°C ±1°C) ± 1.0 mm (at 20°C ±1°C)
InterfaceCommunication protocol for digital IMT transducersCommunication protocol for digital IMT transducersCommunication protocol for digital IMT transducersCommunication protocol for digital IMT transducers
Transfer rate4000 measuring / sec4000 measuring / sec4000 measuring / sec4000 measuring / sec
Supply / Power consumption 5V5V5V5V
120 mW [Run]120 mW [Run]120 mW [Run]120 mW [Run]
15 mW [Idle]15 mW [Idle]15 mW [Idle]15 mW [Idle]
RepairPartially possiblePartially possiblePartially possiblePartially possible

Drawings

Posted on

3TLX50 DG Series (± 5.0 mm)

  • Inductive Halfbridge
  • ± 2.0 mm Measuring Stroke
  • 4.6 mm Total Stroke
  • 0.05 mm Repeatability
  • Supply: 5V
  • Power Consumption: 120 mW [Run] / 15 mW [Idle]

Intelligent transducer with integrated signal conditioning and digital interface. Used for the same applications as our standard transducers with an 8h6 body diameter. 

Measuring stroke ± 2.0 mm and total stroke 4.6 mm. Pretravel not adjustable. Spring push, Vacuum retract, and pneumatic options available. Plug DIN M5, cable exit axial.

Measuring Systems

  • Inductive Halfbridge coil system with core. Integrated conditioning electronics with system error correction.

Connections

  • Connection to transducer – Sensor plug M5, 4 pole 
  • Cable – PUR, pigtail with 200 mm length 
  • Connection to electronics – Sensor plug M8, 4 pole

Interface

  • Freely documented point-to-point protocol on RS485 base, termination 120 ohm.
  • Connection to sensor with 4 wire cable, M5 plug on the sensor side, M8 plug on the electronic side.
  • Baud rates 9600 bit/s, 115200 bit/s, 10 kbit/s, 500 kbit/s and 1 Mbit/s.
  • Sensor information for test equipment monitoring, SPS-profiles and objects.


Technical data

Cable exit:
'A' Axial
'R' Radial
3TLX10A DG / 3TLX10R DG3TLX10AV DG / 3TLX10RV DG3TLX10AP DG / 3TLX10RP DG3TLX10AL DG / 3TLX10RL DG
Total stroke4.6 mm4.6 mm4.6 mm4.6 mm
Measuring stroke (symmetrical)± 2.0 mm± 2.0 mm± 2.0 mm± 2.0 mm
Pre-travelSymmetrical, not adjustableSymmetrical, not adjustableSymmetrical, not adjustableSymmetrical, not adjustable
Bearingball bearing no side-playball bearing no side-playball bearing no side-playball bearing no side-play
Lifetime>10 Mio. Cycles>10 Mio. Cycles>10 Mio. Cycles>10 Mio. Cycles
Tip rotation1° over full stroke1° over full stroke1° over full stroke1° over full stroke
Temperature range-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation
Mounting positionAnyAnyAnyAny
Tip3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread
BellowFPM / FKMFPM / FKMFPM / FKM-
Body diameter8h68h68h68h6
PlugDIN M5DIN M5DIN M5DIN M5
Advance--pneumaticpneumatic
Lift offnoneVacuumReturn springReturn spring
Maximum pressure--1.5 bar4.5 bar
Spring rate0.63 N at electrical zero (tolerance ± 20%)0.63 N at electrical zero (tolerance ± 20%)Approx. 1.0 N at 0.8 bar approx. 0.6 N at 0.6 bar Approx. 1.0 N at 1.1 bar approx. 0.6 N at 0.8 bar (at electrical zero)
0.16 N – 4.0 N optional0.16 N – 1.0 N optional(at electrical zero)
Measuring systemInductive halfbridgeInductive halfbridgeInductive halfbridgeInductive halfbridge
Repeatability0.05 mm0.05 mm0.05 mm0.05 mm
Error limit ± 1.0 mm (at 20°C ±1°C) ± 1.0 mm (at 20°C ±1°C) ± 1.0 mm (at 20°C ±1°C) ± 1.0 mm (at 20°C ±1°C)
InterfaceCommunication protocol for digital IMT transducersCommunication protocol for digital IMT transducersCommunication protocol for digital IMT transducersCommunication protocol for digital IMT transducers
Transfer rate4000 measuring / sec4000 measuring / sec4000 measuring / sec4000 measuring / sec
Supply / Power consumption 5V5V5V5V
120 mW [Run]120 mW [Run]120 mW [Run]120 mW [Run]
15 mW [Idle]15 mW [Idle]15 mW [Idle]15 mW [Idle]
RepairPartially possiblePartially possiblePartially possiblePartially possible

Drawings

Posted on

3TLX50/1-PLG Series (±1.0mm)

3TLX50-PLG Series

  • ± 5.0 mm Measuring Stroke
  • 10.6 mm Total Stroke
  • 0.02 µm Repeatability
  • 1:10 7.38 ± 0.02 mV/(Vmm) Standard Sensitivity
  • 1:5 14.76 ± 0.04 mV/(Vmm) Optional Sensitivity
  • Halfbridge (TESA® Compatible)

For the same application as our standard transducers but with the convenience of a pluggable cable.

The 3TL series transducer with pluggable connection cable for an easy change and replacement, Alignment transducer

Technical data

3TLX50-PLG3TLX50V-PLG3TLX50P-PLG3TLX50L-PLG
Total stroke10.6 mm10.6 mm10.6 mm10.6 mm
Measuring stroke (symmetrical)±5.0 mm±5.0 mm±5.0 mm±5.0 mm
Pre-travelAdjustableAdjustableAdjustableAdjustable
Default Setting-5.5 mm-5.5 mm+5.5 mm+5.5 mm
Bearingball bearing no side-playball bearing no side-playball bearing no side-playball bearing no side-play
Lifetime>10 Mio. Cycles>10 Mio. Cycles->10 Mio. Cycles
Tip rotation1° over full stroke1° over full stroke1° over full stroke1° over full stroke
Temperature range-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation
Mounting positionAnyAnyAnyAny
Tip3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread
BellowFPM / FKMFPM / FKMFPM / FKM-
Body diameter8h68h68h68h6
PlugM8 sensor plugM8 sensor plugM8 sensor plugM8 sensor plug
Advance--pneumaticpneumatic
Lift offnoneVacuum--
Maximum pressure--1.5 bar4.5 bar
Spring rate1 N ±15% (at electrical zero), 1.6N as option1 N ±15% (at electrical zero), 1.6N as option1.5 N at 0.9 bar
2.0N at 1.2 bar (both at electrical zero)
1.0 N at 1.3 bar
1.6 N at 1.7 bar (both at electrical zero)
Repeatability0.02 µm0.02 µm0.02 µm0.02 µm
Linearity error0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
SensitivityStandard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Drive frequency13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%
Supply voltage3.0 V ± 0.5 % RMS3.0 V ±0.5 % RMS3.0 V ±0.5 % RMS3.0 V ± 0.5 % RMS
Coil formHalfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)
Posted on

3TLX50/2-PLG Series (±2.0mm)

3TLX50-PLG Series

  • ± 5.0 mm Measuring Stroke
  • 10.6 mm Total Stroke
  • 0.02 µm Repeatability
  • 1:10 7.38 ± 0.02 mV/(Vmm) Standard Sensitivity
  • 1:5 14.76 ± 0.04 mV/(Vmm) Optional Sensitivity
  • Halfbridge (TESA® Compatible)

For the same application as our standard transducers but with the convenience of a pluggable cable.

The 3TL series transducer with pluggable connection cable for an easy change and replacement, Alignment transducer

Technical data

3TLX50-PLG3TLX50V-PLG3TLX50P-PLG3TLX50L-PLG
Total stroke10.6 mm10.6 mm10.6 mm10.6 mm
Measuring stroke (symmetrical)±5.0 mm±5.0 mm±5.0 mm±5.0 mm
Pre-travelAdjustableAdjustableAdjustableAdjustable
Default Setting-5.5 mm-5.5 mm+5.5 mm+5.5 mm
Bearingball bearing no side-playball bearing no side-playball bearing no side-playball bearing no side-play
Lifetime>10 Mio. Cycles>10 Mio. Cycles->10 Mio. Cycles
Tip rotation1° over full stroke1° over full stroke1° over full stroke1° over full stroke
Temperature range-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation
Mounting positionAnyAnyAnyAny
Tip3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread
BellowFPM / FKMFPM / FKMFPM / FKM-
Body diameter8h68h68h68h6
PlugM8 sensor plugM8 sensor plugM8 sensor plugM8 sensor plug
Advance--pneumaticpneumatic
Lift offnoneVacuum--
Maximum pressure--1.5 bar4.5 bar
Spring rate1 N ±15% (at electrical zero), 1.6N as option1 N ±15% (at electrical zero), 1.6N as option1.5 N at 0.9 bar
2.0N at 1.2 bar (both at electrical zero)
1.0 N at 1.3 bar
1.6 N at 1.7 bar (both at electrical zero)
Repeatability0.02 µm0.02 µm0.02 µm0.02 µm
Linearity error0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
SensitivityStandard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Drive frequency13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%
Supply voltage3.0 V ± 0.5 % RMS3.0 V ±0.5 % RMS3.0 V ±0.5 % RMS3.0 V ± 0.5 % RMS
Coil formHalfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)
Posted on

3TLX50-PLG Series (±5.0mm)

3TLX50-PLG Series

  • ± 5.0 mm Measuring Stroke
  • 10.6 mm Total Stroke
  • 0.02 µm Repeatability
  • 1:10 7.38 ± 0.02 mV/(Vmm) Standard Sensitivity
  • 1:5 14.76 ± 0.04 mV/(Vmm) Optional Sensitivity
  • Halfbridge (TESA® Compatible)

For the same application as our standard transducers but with the convenience of a pluggable cable.

The 3TL series transducer with pluggable connection cable for an easy change and replacement, Alignment transducer

Technical data

3TLX50-PLG3TLX50V-PLG3TLX50P-PLG3TLX50L-PLG
Total stroke10.6 mm10.6 mm10.6 mm10.6 mm
Measuring stroke (symmetrical)±5.0 mm±5.0 mm±5.0 mm±5.0 mm
Pre-travelAdjustableAdjustableAdjustableAdjustable
Default Setting-5.5 mm-5.5 mm+5.5 mm+5.5 mm
Bearingball bearing no side-playball bearing no side-playball bearing no side-playball bearing no side-play
Lifetime>10 Mio. Cycles>10 Mio. Cycles->10 Mio. Cycles
Tip rotation1° over full stroke1° over full stroke1° over full stroke1° over full stroke
Temperature range-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation
Mounting positionAnyAnyAnyAny
Tip3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread
BellowFPM / FKMFPM / FKMFPM / FKM-
Body diameter8h68h68h68h6
PlugM8 sensor plugM8 sensor plugM8 sensor plugM8 sensor plug
Advance--pneumaticpneumatic
Lift offnoneVacuum--
Maximum pressure--1.5 bar4.5 bar
Spring rate1 N ±15% (at electrical zero), 1.6N as option1 N ±15% (at electrical zero), 1.6N as option1.5 N at 0.9 bar
2.0N at 1.2 bar (both at electrical zero)
1.0 N at 1.3 bar
1.6 N at 1.7 bar (both at electrical zero)
Repeatability0.02 µm0.02 µm0.02 µm0.02 µm
Linearity error0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
SensitivityStandard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Drive frequency13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%
Supply voltage3.0 V ± 0.5 % RMS3.0 V ±0.5 % RMS3.0 V ±0.5 % RMS3.0 V ± 0.5 % RMS
Coil formHalfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)
Posted on

3TLX20-PLG Series (±2.0 mm)

3TLX50-PLG Series

  • ± 5.0 mm Measuring Stroke
  • 10.6 mm Total Stroke
  • 0.02 µm Repeatability
  • 1:10 7.38 ± 0.02 mV/(Vmm) Standard Sensitivity
  • 1:5 14.76 ± 0.04 mV/(Vmm) Optional Sensitivity
  • Halfbridge (TESA® Compatible)

For the same application as our standard transducers but with the convenience of a pluggable cable.

The 3TL series transducer with pluggable connection cable for an easy change and replacement, Alignment transducer

Technical data

3TLX50-PLG3TLX50V-PLG3TLX50P-PLG3TLX50L-PLG
Total stroke10.6 mm10.6 mm10.6 mm10.6 mm
Measuring stroke (symmetrical)±5.0 mm±5.0 mm±5.0 mm±5.0 mm
Pre-travelAdjustableAdjustableAdjustableAdjustable
Default Setting-5.5 mm-5.5 mm+5.5 mm+5.5 mm
Bearingball bearing no side-playball bearing no side-playball bearing no side-playball bearing no side-play
Lifetime>10 Mio. Cycles>10 Mio. Cycles->10 Mio. Cycles
Tip rotation1° over full stroke1° over full stroke1° over full stroke1° over full stroke
Temperature range-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation
Mounting positionAnyAnyAnyAny
Tip3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread
BellowFPM / FKMFPM / FKMFPM / FKM-
Body diameter8h68h68h68h6
PlugM8 sensor plugM8 sensor plugM8 sensor plugM8 sensor plug
Advance--pneumaticpneumatic
Lift offnoneVacuum--
Maximum pressure--1.5 bar4.5 bar
Spring rate1 N ±15% (at electrical zero), 1.6N as option1 N ±15% (at electrical zero), 1.6N as option1.5 N at 0.9 bar
2.0N at 1.2 bar (both at electrical zero)
1.0 N at 1.3 bar
1.6 N at 1.7 bar (both at electrical zero)
Repeatability0.02 µm0.02 µm0.02 µm0.02 µm
Linearity error0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
SensitivityStandard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Drive frequency13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%
Supply voltage3.0 V ± 0.5 % RMS3.0 V ±0.5 % RMS3.0 V ±0.5 % RMS3.0 V ± 0.5 % RMS
Coil formHalfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)
Posted on

3TL10-PLG Series (±1.0 mm)

3TLX50-PLG Series

  • ± 5.0 mm Measuring Stroke
  • 10.6 mm Total Stroke
  • 0.02 µm Repeatability
  • 1:10 7.38 ± 0.02 mV/(Vmm) Standard Sensitivity
  • 1:5 14.76 ± 0.04 mV/(Vmm) Optional Sensitivity
  • Halfbridge (TESA® Compatible)

For the same application as our standard transducers but with the convenience of a pluggable cable.

The 3TL series transducer with pluggable connection cable for an easy change and replacement, Alignment transducer

Technical data

3TLX50-PLG3TLX50V-PLG3TLX50P-PLG3TLX50L-PLG
Total stroke10.6 mm10.6 mm10.6 mm10.6 mm
Measuring stroke (symmetrical)±5.0 mm±5.0 mm±5.0 mm±5.0 mm
Pre-travelAdjustableAdjustableAdjustableAdjustable
Default Setting-5.5 mm-5.5 mm+5.5 mm+5.5 mm
Bearingball bearing no side-playball bearing no side-playball bearing no side-playball bearing no side-play
Lifetime>10 Mio. Cycles>10 Mio. Cycles->10 Mio. Cycles
Tip rotation1° over full stroke1° over full stroke1° over full stroke1° over full stroke
Temperature range-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation
Mounting positionAnyAnyAnyAny
Tip3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread3 mm tungsten carbide ball, M2.5 fixing thread
BellowFPM / FKMFPM / FKMFPM / FKM-
Body diameter8h68h68h68h6
PlugM8 sensor plugM8 sensor plugM8 sensor plugM8 sensor plug
Advance--pneumaticpneumatic
Lift offnoneVacuum--
Maximum pressure--1.5 bar4.5 bar
Spring rate1 N ±15% (at electrical zero), 1.6N as option1 N ±15% (at electrical zero), 1.6N as option1.5 N at 0.9 bar
2.0N at 1.2 bar (both at electrical zero)
1.0 N at 1.3 bar
1.6 N at 1.7 bar (both at electrical zero)
Repeatability0.02 µm0.02 µm0.02 µm0.02 µm
Linearity error0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
0.8 % FS
± 5000 mm range
(at 20°C ±1°C)
SensitivityStandard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Standard setting 1:10
7.38 ± 0.02 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Optional Setting 1:5
14.76 ± 0.04 mV / (Vmm) (into R = 2KOhm ±0.1%)
Drive frequency13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%
Supply voltage3.0 V ± 0.5 % RMS3.0 V ±0.5 % RMS3.0 V ±0.5 % RMS3.0 V ± 0.5 % RMS
Coil formHalfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)Halfbridge (TESA® compatible)
Posted on

Peter Hirt BMT500

File Download
Link

Peter Hirt T802 (1002226) Half bridge Block Gauge with 73.75 mm/Vmm sensitivity and ± 1 mm measuring stroke, Pre travel adjustable. Cable 2 m, cable exit radial.

Peter Hirt T852 T802 block gauge transducer

For the precision measurement of bores and cavities.

Block Gauge series T800 are used for the precision measurement of bores and cavities. The mountable body makes this series easy to install into a fixture.

There are numerous accessories available such as a pneumatic cylinder and horizontal / vertical tip holders.

Cable exit:
'1' Axial
'2' Radial
T801T802T851T852
Total stroke6.0 mm6.0 mm6.0 mm6.0 mm
Measuring stroke (symmetrical)±1.0 mm±1.0 mm±1.0 mm±1.0 mm
Pre-travelAdjustableAdjustableAdjustableAdjustable
Default Setting-1.2 mm-1.2 mm+2.8 mm+2.8 mm
Bearingball bearing no side-playball bearing no side-playball bearing no side-playball bearing no side-play
Lifetime>10 Mio. Cycles>10 Mio. Cycles->10 Mio. Cycles
Tip rotation1° over full stroke1° over full stroke1° over full stroke1° over full stroke
Temperature range-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation-10 to +65°C, storage and operation
Mounting positionAnyAnyAnyAny
TipMountableMountableMountableMountable
Dimension70 x 58 x 12 mm70 x 58 x 12 mm70 x 58 x 12 mm70 x 58 x 12 mm
CablePUR shielded, length 2mPUR shielded, length 2mPUR shielded, length 2mPUR shielded, length 2m
Plug5 pin, 270°5 pin, 270°5 pin, 270°5 pin, 270°
AdvanceMountableMountableMountableMountable
Spring rate1 N ± 15% (at electrical zero), 1.6 N as option1 N ± 15% (at electrical zero), 1.6 N as option1 N ± 15% (at electrical zero), 1.6 N as option1 N ± 15% (at electrical zero), 1.6 N as option
Repeatability0.01 µm0.01 µm0.01 µm0.01 µm
Linearity error0.25 % FS
± 1000 mm range
(at 20°C ±1°C)
0.25 % FS
± 1000 mm range
(at 20°C ±1°C)
0.25 % FS
± 1000 mm range
(at 20°C ±1°C)
0.25 % FS
± 1000 mm range
(at 20°C ±1°C)
Sensitivity73.75 ± 0.15 mV/(Vmm)
(into R = 2kOhm ±0.1%)
73.75 ± 0.15 mV/(Vmm)
(into R = 2kOhm ±0.1%)
73.75 ± 0.15 mV/(Vmm)
(into R = 2kOhm ±0.1%)
73.75 ± 0.15 mV/(Vmm)
(into R = 2kOhm ±0.1%)
Drive frequency13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%13 kHz ± 5%
Supply voltage3.0 V ± 0.5 % RMS3.0 V ±0.5 % RMS3.0 V ±0.5 % RMS3.0 V ± 0.5 % RMS
Coil formHalfbridge (TESA® compatible)Halfbridge (TESA® compatible)Fullbridge (LVDT)Fullbridge (LVDT)