Category: Counter, Electronics & Displays

Magnescale LT10A

File Download
Link

Compact, lightweight, and easy-to-mount counter.

Key features

  • Compact size : DIN standard (72 mm x 72 mm / 2.83″ x 2.83″ W x H)
  • Resolution : 5,10 μm Selectable
  • Suitable for panel mounting
  • Direct interfacing from display unit to PLC or computer
  • Current values, maximum, minimum, peak-to-peak values and GO/NO GO evaluation included as standard functions.
  • ADD/SUB function (2-channel model)
  • Full lineup for various applications
ModelLT10A-105LT10A-105BLT10A-105CLT10A-205LT10A-205BLT10A-205C
Display6 digit backlit LCD, mode display
I/OMeasuring unit input1 CH2 CH
I/O connectors *1O
BCD *2-O--O-
RS-232C *3--O--O
RS-TRG *4--O--O
Reset functionReset key or external input (I/O connectors)
-BCD terminalRS-232C command-BCD terminalRS-232C command
Preset functionPreset value set with preset key, recalled with reset key
-Recalled with BCD reset terminal Set or recalled with RS-232C command-Recalled with BCD reset terminal Set or recalled with RS-232C command
Comparator functionThree-level comparator Comparator value set with keys on the front panel. Result evaluation: LED and I/O connector output (photocoupler)
-Up to 4 values can be set for comparator (key input). Switched with BCD terminal.Set with RS-232C command -Up to 4 values can be set for comparator (key input). Switched with BCD terminal. Set with RS-232C command
Peak hold function
Set with RS-232C command
Peak hold functionMaximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input.
--RS-232C can set or start--RS232C can set or start
Input resolution0.0005 mm, 0.01 mm selectable
Display resolution0.0005 mm, 0.01 mm selectable
DirectionCan be switched
Reference point functionFunction use enabled/disabled can be selected (if use is enabled, the unit enters reference point signal input wait status at the same time as power-on).
Maximum response speed100 m/min
Addition and subtraction function-A+B, A-B, B-A can be set with the direction setting
AlarmSpeed over or measuring unit cable disconnected (Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF).)
-BCD alarm terminal "H" (OFF)--BCD alarm terminal "H" (OFF)-
Data storageResolution, direction, comparator value, preset value, modes, etc.
-BCD signData signalling rate, etc-BCD sign, etcData signalling rate, etc.
Key lock functionKey lock and release
TemperatureOperating: 0 ~ 40°C, Storage: -10 ~50°C
Power consumption *51.8W2.9W2.0W2.3W4.0W2.5W
MassApprox. 200gApprox. 230gApprox. 220gApprox. 210gApprox. 270gApprox. 230g
Power supply Power input connector (3 pins): DC 9.0 - 26.4 V
Compatible measuring unit DT12/32 series
*1 I/O connector Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only) Output : Result evaluation (photocoupler)
*2 BCD (36 pin half-pitch connector) Input : Reset, peak-hold start, comparator value selection (4 settings) Output : five digits (open collector)One of current value/maximum value/minimum value/peak-to-peak value selected and output. Alarm output
*3 RS-232C (8 pin mini-DIN connector) Reset, preset value setting/recall, peak-hold start, peak-hold pause
*4 RS-TRG pin Trigger input for RS-232C data output
*5 With measuring unit connected.

Related products

Counter LY71

Magnescale LG20

General use digital readout Key features Selectable display resolution Scale input signal: A/B quadrature signal…

Learn more
Counter LY71

Magnescale LY72

For measurements and control in diverse field uses. Multifunction counter with RS-232C interface Key features…

Learn more
Magnescale Digital Gauge LT20A counter picture

Magnescale LT20A

Compact, lightweight, and easy-to-mount counter Key features Compact design : DIN standard size (72 mm…

Learn more
Magnescale Digital Gauge LT30 counter picture

Magnescale LT30

Counter compatible with our compact, high-precision DK series of digital gauges Key features Maxmum display…

Learn more
Please enable JavaScript in your browser to complete this form.